SP80B Handheld Spirometer with Colour LCD, Rechargeable Lithium Battery, Bluetooth and USB Data Transfer for Lung Function Monitoring, FVC, FEV1 and PEF Tests
SP80B Handheld Spirometer with Bluetooth, Colour LCD and Rechargeable Lithium Battery

The SP80B handheld spirometer is intended for checking lung conditions through routine testing in hospitals, clinics and family settings. Using infrared signal acquisition, it measures forced vital capacity and related volume and flow values, including FEV1, PEF and the FEV1/FVC ratio. A 2.8-inch colour LCD presents test information alongside flow-volume, volume-time and trend charts. Records can be stored, reviewed, deleted or uploaded, with Bluetooth and USB cable transfer available. The 190 g monitor measures 160 mm × 65 mm × 45 mm and runs from a rechargeable lithium battery. One-button measurement, calibration, test indicators and over-limit prompts support operation, while PC software is identified in the supplied product information without further compatibility details.
Respiratory Measurements and Test Feedback
The monitor combines several respiratory measurements with on-screen feedback, allowing test results to be reviewed as numerical values, charts and trends. Its functions focus on routine FVC-related testing rather than treatment.
FVC FEV1 and Ratio
The SP80B measures forced vital capacity, or FVC, and forced expiratory volume in one second, or FEV1. It also calculates the FEV1/FVC ratio, bringing these three commonly referenced values into the same testing record. Personnel information can be entered before measurement, including height, age and sex, so the relevant user details accompany the test process. The volume measurement range extends from 0 to 10 L. Stated volume accuracy is ±3% or ±0.05 L, whichever is greater. These figures describe measurement performance; the source does not specify diagnostic thresholds, interpretation services or treatment functions.
Flow and Volume Indicators
In addition to peak expiratory flow, the spirometer measures forced expiratory flow at 25%, 50% and 75% of FVC, listed as FEF25, FEF50 and FEF75. It also measures FEF2575, covering forced expiratory flow from 25% to 75% of FVC. The overall flow range is 0–16 L/s, with stated accuracy of ±5% or ±0.2 L/s, whichever is greater. Volume and flow over-limit prompts provide feedback during use, and dedicated indicators show expiration within six seconds. Measurement begins through a one-button control, reducing the number of operating steps stated in the product information.
Charts Trends and Alerts
Test information can be viewed as a flow-volume chart or a volume-time chart, providing two graphical representations of a measurement. A trend-chart display is also included for reviewing changes across retained data. The health-state indication function supplies an additional status reference, although its assessment criteria are not detailed in the source. Volume and flow prompts flag readings that exceed the relevant limits, while battery-power indication keeps the remaining power status visible. Together, these displays organise measurement, status and device information on the 2.8-inch screen without requiring separate charting equipment for the listed on-device views.
Data Handling and Everyday Operation
Stored records, two transfer methods and a set of device controls give the SP80B defined data-handling functions. The available information distinguishes these capabilities without stating storage capacity or software requirements.
Bluetooth USB and PC Software
Data can be transmitted wirelessly by Bluetooth or through a wired USB connection. One USB cable is included, so the physical lead needed for the stated cable connection is supplied with the monitor. Records can also be uploaded from the device, alongside the options to store, delete and review them. PC software is named in the product title, supporting its relevance to computer-based data handling. However, the source does not identify supported Windows versions, other operating systems, installation media, export formats or specific analysis tools. Those details should therefore be checked against the software documentation rather than assumed.
Controls Display and Stored Data
The 2.8-inch LCD is the main display for measurements, charts, clock information and device status. One-button measurement provides a direct start control, while stored data can be reviewed on the monitor and deleted or uploaded when required. Automatic shutdown occurs after two minutes without operation, and battery-power indication is built into the display functions. The real-time clock can be set and shown, providing time information for the device. No numerical memory capacity, maximum patient-record count or wireless transmission distance is supplied, so the data-management description remains limited to the functions explicitly listed.
Power Clock and Calibration
A rechargeable lithium battery powers the SP80B, and the stated working current is 200 mA. The safety classification is internally powered equipment with a type BF applied part. Battery status is indicated on the monitor, and the two-minute inactivity shutdown provides a defined automatic power-off behaviour. Calibration is included as a device function, although the source does not set out a calibration interval or a separate calibration kit. The real-time clock can be adjusted and displayed as needed. Battery capacity, charging time, charge cycles and expected runtime are not provided and should not be inferred from the rechargeable power specification.
Size Accuracy and Intended Settings
The physical specification, measurement tolerances and listed test environments help define where the SP80B fits. Its handheld format is supported by exact dimensions and weight rather than unstated carrying or enclosure claims.
Handheld Dimensions and Battery
The enclosure measures 160 mm in length, 65 mm in width and 45 mm in height. At 190 g, the monitor has a stated handheld weight that can be compared directly with other equipment specifications. Its 2.8-inch colour LCD is integrated into this format, removing the need for a separate display for the listed charts and readings. Power is supplied internally by the rechargeable lithium battery. The construction materials of the outer casing and screen are not disclosed, so no claims are made about impact resistance, water resistance or specialist cleaning compatibility. A user manual and USB cable accompany the device.
Measurement Ranges and Accuracy
For volume testing, the specified range is 0–10 L. Accuracy is stated as ±3% or ±0.05 L, whichever value is greater, giving two explicit limits that depend on the reading. Flow measurement covers 0–16 L/s, with accuracy of ±5% or ±0.2 L/s, again using whichever value is greater. These specifications apply to the monitor’s measurement performance and should be considered alongside its calibration function. The product information does not provide additional environmental operating limits, repeatability figures or certification details. Working current is 200 mA, and the applied-part classification is type BF.
Routine Testing and Supplied Accessories
The SP80B is listed for routine tests in hospitals, clinics and family environments. Its package includes one user manual, one USB cable and one disposable mouthpiece, alongside the handheld monitor. The mouthpiece is identified as a disposable accessory, but no additional mouthpiece quantity or spare pack is stated. In use, personnel details can be entered, measurement started with the one-button control and resulting records reviewed or transferred. The device supplies respiratory measurements and status indications; it does not state that it replaces professional assessment. PC software is referenced, but buyers requiring a particular operating system or reporting format should verify those details before purchase.